Performance Properties
- Tensile Bond Strength:
ASTM C 932-05 (modified) (pulling apart bonded cement briquet halves). 265 psi. Avg. 14 days.
- Flexural Bond Strength:
ASTM C-78 (concrete beams laminated with bonding agent). 603 psi. Avg.
- Shear Bond Strength:
ASTM C-1059 (slant shear cylinder test). 740 psi. Avg. 14 days.
- Temperature Range:
ASTM C-109 (specimens brought to 35 degrees F for 1 hr., then to 310 degrees F for 2 hrs). No bond failure. Shear tests 400 psi. Avg.
- Freeze-Thaw Stability:
5 cycles freeze (-10 degrees F and thaw). Freeze-thaw stable.
- Toxicity:
Enclosed mice exposed to 30 cc volatized bonding agent for 1 hr. Non-toxic, no ill effects after 7 days.
- Fire Resistance:
ASTM E-119 (bonded assembly). Passed 2 hr. Fire Test 1800 degrees F and 1 hr. Hose Stream Test.
- Flammability:
Meets MIL-B-19235C, non-flammable.
- Acid Resistance:
1″ concrete slabs bonded to 1/2″ gypsum plaster subjected to seepage of strong detergents and synthetic urine for 10 hrs. a day. No bond failure after 25 consecutive days. Also unaffected by alkalinity of cement.
- Life Expectancy:
Lab tested and field proven. Non-deteriorating bond; retains strength and flexibility.