Plaster-Weld Performance Properties

Plaster-Weld Performance Properties

Data obtained from tests conducted periodically by leading independent laboratories. Test reports are available upon request.

  • Tensile Bond Strength:
    ASTM C-631 (pulling apart bonded cement briquet halves). In all cases failure occurred in the cementitious material, not in the bond. 385 psi. Avg. 28 days.
     
  • Temperature Range:
    ASTM C-109 (specimens brought to 35 degrees F for 1 hr., then to 310 degrees F for 2 hrs). No bond failure. Shear tests 400 psi. Avg.
     
  • Freeze-Thaw Stability:
    5 cycles freeze (-10 degrees F and thaw). Freeze-thaw stable.
     
  • Toxicity:
    Enclosed mice exposed to 30 cc volatized bonding agent for 1 hr. Non-toxic, no ill effects after 7 days.
     
  • Fire Resistance:
    ASTM E-119 (bonded assembly). Passed 2 hr. Fire Test 1800 degrees F and 1 hr. Hose Stream Test.
     
  • Flammability:
    Meets MIL-B-19235C, non-flammable.
     
  • Acid Resistance:
    1″ concrete slabs bonded to 1/2″ gypsum plaster subjected to seepage of strong detergents and synthetic urine for 10 hrs. a day. No bond failure after 25 consecutive days. Also unaffected by alkalinity of cement.
     
  • Life Expectancy:
    Lab tested and field proven. Non-deteriorating bond; retains strength and flexibility.